A cable is only as good as its conductor purity, insulation concentricity, stranding geometry and jacket integrity. Here is how we build wire and cable that keeps working for decades.

๐ŸŸ 

100% Bare Copper Conductors

Conductors are drawn from oxygen-free copper rod โ€” never copper-clad aluminum or recycled low-grade alloy. Solid Class 1 conductors for fixed BV wiring, stranded Class 2 for power cables, and fine-wire Class 5/6 stranding for flexible cords. Bare copper delivers the full conductivity the standards assume: correct ampacity, low voltage drop and stable resistance over decades of service.

๐Ÿงต

Insulation: PVC & XLPE

PVC insulation (types 60227 IEC 01/02/05/52) is extruded with tight concentricity control for building wires and flexible cords โ€” rated 70 ยฐC with flame-retardant grades for house wiring. Cross-linked polyethylene (XLPE) insulation on YJV power cables allows higher conductor temperatures (90 ยฐC) and roughly 20% more ampacity than PVC at the same cross-section.

๐ŸŒ€

Stranding & Cabling

Flexible cords are stranded from fine wires โ€” the more and finer the wires, the more flex cycles the cable survives. Multi-core cables are cabled with controlled lay length and fill factor so the round cross-section stays stable, then bound with tape before sheathing. The result: cables that bend, coil and route without premature conductor fatigue.

๐Ÿ›ก๏ธ

Screening & Armour

RVVP control cables carry a tinned copper braid screen (85% minimum coverage) that drains interference to earth and keeps signals clean next to power circuits. YJV22 power cables add a steel-tape armour layer under the outer sheath โ€” protecting the cable from impact, crushing and rodent damage in buried and industrial installations.

๐Ÿงฅ

Jackets: PVC & Rubber

PVC sheaths for general indoor and outdoor use; rubber sheaths (H07RN-F) for heavy service โ€” oil-resistant, weather-resistant and flexible down to -25 ยฐC. Jackets are extruded in-house with diameter control, and can be printed with your brand, cable type, voltage rating and sequential length marks.

๐Ÿ“

Electrical Testing

Every production lot is tested: conductor resistance, insulation resistance, 2 kV/2.5 kV high-voltage (spark) test, and dimensional checks on conductor and insulation. Flexible cords are flex-tested per standard. Lot test reports are available on request โ€” for tenders, quality audits and distributor programs.

๐Ÿ“ฆ

Export Packaging

100 m coils with shrink-wrap and label, wooden/steel drums for power cable up to 2000 m, and carton programs for flexible cords. Custom printing, colors and packing configurations are available for OEM programs.

โœ…

Certifications

Production follows GB/T 5023, IEC 60227, IEC 60502-1, UL 83 and VDE 0281. Products carry CE, RoHS and REACH documentation, with CCC (China Compulsory Certification) on domestic models. UL/CSA and VDE certification files are available for the corresponding wire types.